Ryan Malloy 30b482a8cb HA integration: wire v1+UDP into the coordinator + config flow
OmniClientV1Adapter (src/omni_pca/v1/adapter.py)
  V2-shape facade over OmniClientV1. Exposes the OmniClient surface the
  HA coordinator was written against — get_system_information,
  list_*_names, get_object_properties (synthesized from streamed names),
  get_extended_status (chunked, routed to v1 typed status opcodes),
  get_object_status(AREA, ...) (derived from SystemStatus.area_alarms),
  events() (EventStream on v1 SystemEvents opcode 35), plus all the
  write-method shims.

  Chunks unit/zone/thermostat/aux polls per-type because firmware 2.12
  NAKs Request*Status with >~62 records in one shot (verified live).
  Falls back to "Area 1".."Area 8" when the UploadNames stream returns
  zero areas — common on panels where the installer didn't name them.

custom_components/omni_pca/coordinator.py
  _ensure_connected picks OmniClientV1Adapter for transport=udp. New
  _walk_properties_v1 replaces the v2 RequestProperties walk with a
  name-stream + synthesized-Properties pass.

custom_components/omni_pca/config_flow.py
  _probe routes to OmniClientV1Adapter for transport=udp instead of
  trying to drive v2 OmniClient over UDP (which silently dropped after
  handshake, per the earlier diagnosis).

src/omni_pca/events.py
  parse_events / _ensure_system_events / EventStream now take an
  expected_opcode arg (default v2 SystemEvents=55, v1 callers pass 35).
  Word format is byte-identical between v1 and v2, so the typed-event
  decoder is unchanged.

src/omni_pca/v1/client.py
  _range_status supports the long-form RequestUnitStatus (BE u16
  start/end) so panels with unit indices > 255 (sprinklers, flags) work.

Verified end-to-end against firmware 2.12 panel at 192.168.1.9:
  config entries:
    state=loaded  Omni Pro II (host.docker.internal)  (mock)
    state=loaded  Omni Pro II (192.168.1.9)           (real, v1+UDP)
  real-panel entities created in HA: 96 (30 binary_sensor, 26 light,
  15 switch, 13 button, 9 sensor, 3 climate)
  cross-check: light.omni_pro_ii_front_porch_2 = on  (matches live
  probe: unit #2 'FRONT PORCH' state=0x01 brightness=100)

dev/probe_v1_coordinator.py
  Coordinator-shaped end-to-end smoke test against the real panel
  without HA — drives the full discovery + poll cycle through the
  adapter. Useful for regression-checking the v1 wire path.

dev/add_real_panel.py
  Programmatically adds the real-panel config entry to the dev HA
  stack via the REST config-flow endpoints. Idempotent.
2026-05-11 01:30:49 -06:00
..

HAI / Leviton Omni Panel — Home Assistant Integration

Native HA integration that talks Omni-Link II directly to your Omni Pro II / Omni IIe / Omni LTe / Lumina controller over TCP. No middleware — HA opens an encrypted session straight to the panel and listens for unsolicited push messages.

This integration is the HA-facing wrapper around the omni-pca Python library; the library handles the wire protocol, this component surfaces it as HA entities.

Install

  1. HACS → Integrations → custom repository → add https://git.supported.systems/warehack.ing/omni-pca, category Integration.
  2. Install HAI / Leviton Omni Panel, then restart Home Assistant.

Manual

Copy the custom_components/omni_pca/ directory into your HA config/custom_components/ directory and restart HA.

Configure

  1. Settings → Devices & Services → Add Integration → search for HAI/Leviton Omni Panel.
  2. Enter:
    • Host — IP or hostname of the panel (e.g. 192.168.1.50)
    • Port — defaults to 4369 (HAI's reserved port)
    • Controller Key — 32 hex characters, the panel's NVRAM key
  3. Save. The panel appears as a single device with entities per object.

Where do I get the Controller Key?

If you have a .pca configuration export from PC Access, the included CLI extracts the key for you:

uvx omni-pca decode-pca '/path/to/My House.pca' --field controller_key

Otherwise, find it in PC Access under the panel's Setup → Misc → Network page (HAI labels it "Encryption Key 1").

Entities created

One device per panel, plus per-object entities below.

Platform Entity Per
alarm_control_panel Area arm/disarm with code discovered area
binary_sensor Zone open/tripped binary zone
binary_sensor Zone bypassed (diagnostic) binary zone
binary_sensor AC power, backup battery, system trouble panel
button Panel button macro discovered button
climate Thermostat (heat/cool/auto, fan, hold) discovered thermostat
event Typed push event relay panel
light Unit on/off + brightness discovered unit
sensor Analog zone (temp/humidity/power) analog zone
sensor Thermostat current temp / humidity / outdoor temp thermostat
sensor Panel model + firmware, last event class panel
switch Zone bypass toggle binary zone

State propagates via the panel's unsolicited push messages: zone changes, arming changes, AC/battery troubles, etc. all arrive within one TCP round- trip. A 30-second background poll backstops anything that didn't push.

Services

Service Purpose
omni_pca.bypass_zone Bypass a zone by 1-based index
omni_pca.restore_zone Restore a previously-bypassed zone
omni_pca.execute_program Run a stored program by index
omni_pca.show_message Display a stored message on consoles
omni_pca.clear_message Clear a displayed message
omni_pca.acknowledge_alerts Clear all outstanding troubles/alerts
omni_pca.send_command Power-user escape hatch (raw Command opcode)

Every service takes an entry_id so it picks the right panel when you have multiple configured.

Automation example

React to any alarm activation in real time:

automation:
  - alias: Notify on alarm
    trigger:
      - platform: event
        event_type: state_changed
        event_data:
          entity_id: event.panel_events
    condition: >
      {{ trigger.event.data.new_state.attributes.event_type ==
         "alarm_activated" }}
    action:
      - service: notify.mobile_app
        data:
          title: ALARM
          message: >
            Area {{ trigger.event.data.new_state.attributes.area_index }}

Diagnostics

Settings → Devices & Services → HAI/Leviton Omni Panel → ⋮ → Download diagnostics dumps a redacted snapshot (controller key removed, zone names hashed) — useful for bug reports.

Troubleshooting

  • Won't connect: confirm port 4369 is open on the panel. The Omni Pro II's network module ships off by default; enable it under Setup → Misc → Network on a console.
  • Authentication failed: re-check the Controller Key. The integration triggers HA's reauth flow when the panel rejects the key.
  • No entities for X: only objects with a name configured on the panel are discovered. PC Access's "Names" page is where they live.