Adds CONF_PCA_PATH + CONF_PCA_KEY config-flow fields. When set, the
coordinator parses programs from the .pca file at that path instead
of streaming them over the wire on every entry refresh. Useful for:
* deployments where wire enumeration is slow (1500-slot iteration)
* offline snapshots when the panel is unreachable
* deterministic test setups against a known fixture
The config-flow validates the file is readable and decrypts cleanly,
surfacing pca_not_found / pca_decode_failed errors via the strings/
en.json translations.
The .pca path is checked first in _discover_programs; if absent the
wire path runs as before. So existing deployments are unaffected.
Tests cover the success path (live fixture, 330 programs) and the
two validation failures (missing file, garbage bytes).
OmniClientV1Adapter (src/omni_pca/v1/adapter.py)
V2-shape facade over OmniClientV1. Exposes the OmniClient surface the
HA coordinator was written against — get_system_information,
list_*_names, get_object_properties (synthesized from streamed names),
get_extended_status (chunked, routed to v1 typed status opcodes),
get_object_status(AREA, ...) (derived from SystemStatus.area_alarms),
events() (EventStream on v1 SystemEvents opcode 35), plus all the
write-method shims.
Chunks unit/zone/thermostat/aux polls per-type because firmware 2.12
NAKs Request*Status with >~62 records in one shot (verified live).
Falls back to "Area 1".."Area 8" when the UploadNames stream returns
zero areas — common on panels where the installer didn't name them.
custom_components/omni_pca/coordinator.py
_ensure_connected picks OmniClientV1Adapter for transport=udp. New
_walk_properties_v1 replaces the v2 RequestProperties walk with a
name-stream + synthesized-Properties pass.
custom_components/omni_pca/config_flow.py
_probe routes to OmniClientV1Adapter for transport=udp instead of
trying to drive v2 OmniClient over UDP (which silently dropped after
handshake, per the earlier diagnosis).
src/omni_pca/events.py
parse_events / _ensure_system_events / EventStream now take an
expected_opcode arg (default v2 SystemEvents=55, v1 callers pass 35).
Word format is byte-identical between v1 and v2, so the typed-event
decoder is unchanged.
src/omni_pca/v1/client.py
_range_status supports the long-form RequestUnitStatus (BE u16
start/end) so panels with unit indices > 255 (sprinklers, flags) work.
Verified end-to-end against firmware 2.12 panel at 192.168.1.9:
config entries:
state=loaded Omni Pro II (host.docker.internal) (mock)
state=loaded Omni Pro II (192.168.1.9) (real, v1+UDP)
real-panel entities created in HA: 96 (30 binary_sensor, 26 light,
15 switch, 13 button, 9 sensor, 3 climate)
cross-check: light.omni_pro_ii_front_porch_2 = on (matches live
probe: unit #2 'FRONT PORCH' state=0x01 brightness=100)
dev/probe_v1_coordinator.py
Coordinator-shaped end-to-end smoke test against the real panel
without HA — drives the full discovery + poll cycle through the
adapter. Useful for regression-checking the v1 wire path.
dev/add_real_panel.py
Programmatically adds the real-panel config entry to the dev HA
stack via the REST config-flow endpoints. Idempotent.
custom_components/omni_pca/const.py:
+ CONF_TRANSPORT, TRANSPORT_TCP, TRANSPORT_UDP, DEFAULT_TRANSPORT='tcp'
custom_components/omni_pca/config_flow.py:
+ 'transport' field in _USER_SCHEMA with vol.In([tcp, udp]),
default tcp (so existing flows are unchanged)
+ transport stored in entry.data on create
+ reauth carries the existing transport over from entry.data
+ _probe() takes transport=, propagates to OmniClient
custom_components/omni_pca/coordinator.py:
+ transport= constructor arg, defaults to 'tcp'
+ _ensure_connected passes transport= through to OmniClient
custom_components/omni_pca/__init__.py:
+ reads transport from entry.data (default tcp), passes to coordinator
Backward-compat: existing config entries without a transport key fall
through to 'tcp', identical to current behavior. New entries get the
choice at the config-flow form. The reauth step preserves the existing
transport so users don't have to re-pick it.
357 tests pass; ruff clean across src/ tests/ custom_components/.
HA integration tests don't need updating because they don't pass
transport= explicitly (default tcp matches the mock's default).
custom_components/omni_pca/ — drop-in HA integration:
- manifest.json (HA 2026.x, iot_class=local_push, requires omni-pca lib)
- config_flow.py — host/port/controller_key with auth + reauth steps,
parse_controller_key() extracted as pure testable function
- coordinator.py — OmniDataUpdateCoordinator with long-lived OmniClient,
unsolicited push wiring, ConfigEntryAuthFailed on bad key, reconnect on err
- binary_sensor.py — one entity per named zone, zone_type -> device_class map
(OPENING/MOTION/SMOKE/etc), is_on derived from ZoneProperties.status
- const.py, strings.json, translations/en.json, README.md
- hacs.json at root for HACS distribution
tests: 97 pass + 2 skip (HA harness not installed; importorskip in
test_ha_imports.py). 12 cases for parse_controller_key validation.
Ruff clean across src/ tests/ custom_components/. Status of HA component
itself NOT validated against a running HA — needs that next.