OmniClientV1Adapter (src/omni_pca/v1/adapter.py)
V2-shape facade over OmniClientV1. Exposes the OmniClient surface the
HA coordinator was written against — get_system_information,
list_*_names, get_object_properties (synthesized from streamed names),
get_extended_status (chunked, routed to v1 typed status opcodes),
get_object_status(AREA, ...) (derived from SystemStatus.area_alarms),
events() (EventStream on v1 SystemEvents opcode 35), plus all the
write-method shims.
Chunks unit/zone/thermostat/aux polls per-type because firmware 2.12
NAKs Request*Status with >~62 records in one shot (verified live).
Falls back to "Area 1".."Area 8" when the UploadNames stream returns
zero areas — common on panels where the installer didn't name them.
custom_components/omni_pca/coordinator.py
_ensure_connected picks OmniClientV1Adapter for transport=udp. New
_walk_properties_v1 replaces the v2 RequestProperties walk with a
name-stream + synthesized-Properties pass.
custom_components/omni_pca/config_flow.py
_probe routes to OmniClientV1Adapter for transport=udp instead of
trying to drive v2 OmniClient over UDP (which silently dropped after
handshake, per the earlier diagnosis).
src/omni_pca/events.py
parse_events / _ensure_system_events / EventStream now take an
expected_opcode arg (default v2 SystemEvents=55, v1 callers pass 35).
Word format is byte-identical between v1 and v2, so the typed-event
decoder is unchanged.
src/omni_pca/v1/client.py
_range_status supports the long-form RequestUnitStatus (BE u16
start/end) so panels with unit indices > 255 (sprinklers, flags) work.
Verified end-to-end against firmware 2.12 panel at 192.168.1.9:
config entries:
state=loaded Omni Pro II (host.docker.internal) (mock)
state=loaded Omni Pro II (192.168.1.9) (real, v1+UDP)
real-panel entities created in HA: 96 (30 binary_sensor, 26 light,
15 switch, 13 button, 9 sensor, 3 climate)
cross-check: light.omni_pro_ii_front_porch_2 = on (matches live
probe: unit #2 'FRONT PORCH' state=0x01 brightness=100)
dev/probe_v1_coordinator.py
Coordinator-shaped end-to-end smoke test against the real panel
without HA — drives the full discovery + poll cycle through the
adapter. Useful for regression-checking the v1 wire path.
dev/add_real_panel.py
Programmatically adds the real-panel config entry to the dev HA
stack via the REST config-flow endpoints. Idempotent.
Some Omni network modules are configured for UDP, in which case PC Access
falls back to the v1 wire protocol (OmniLinkMessage outer = 0x10, inner
StartChar 0x5A, typed Request*Status opcodes) instead of v2's TCP path
(OmniLink2Message + StartChar 0x21 + parameterised RequestProperties).
This adds a parallel implementation rather than overloading the v2 path.
omni_pca/v1/
connection.py UDP-only OmniConnectionV1; reuses crypto + handshake,
routes post-handshake messages through OmniLinkMessage
(0x10) wrapping v1 inner format. Adds iter_streaming
for the lock-step UploadNames/Acknowledge/EOD pattern.
messages.py Block parsers for the typed v1 status replies (zone,
unit, thermostat, aux), v1 SystemStatus, and NameData
(handles both one-byte and two-byte NameNumber forms).
client.py OmniClientV1: read API (get_system_information,
get_*_status), discovery (iter_names + list_*_names),
write API (execute_command, execute_security_command,
turn_unit_*, set_unit_level, bypass/restore_zone,
execute_button, set_thermostat_*). acknowledge_alerts
is a no-op (v1 has no equivalent opcode).
Discovery uses bare UploadNames; panel streams every defined name across
all types in a fixed order with per-record Acknowledge. Verified against
firmware 2.12 — pulled 16 zones, 44 units, 16 buttons, 8 codes,
2 thermostats, 8 messages in one stream.
src/omni_pca/message.py
Fix flipped START_CHAR_V1_* constants. enuOmniLinkMessageFormat says
Addressable=0x41 and NonAddressable=0x5A; our names had them swapped.
Wire bytes were unchanged, so existing tests kept passing — but
encode_v1() with no serial_address now correctly emits 0x5A, which
is what UDP needs.
tests/
test_v1_messages.py 22 cases; payloads are real wire captures
from a firmware-2.12 panel via probe_v1_recon.
test_v1_client_commands.py 20 cases; payload-packing for the Command
and ExecuteSecurityCommand opcodes,
including BE u16 parameter2 and the
digit-by-digit security code form.
dev/
probe_v1.py Phase-1 smoke: handshake + RequestSystemInformation.
probe_v1_recon.py Raw opcode dump for protocol reconnaissance.
probe_v1_stream.py Streaming UploadNames flow exploration.
probe_v1_client.py Full read-path smoke test via OmniClientV1.
probe_v1_write.py Live no-op execute_command round-trip.
.gitignore: ignore dev/.omni_key (probe scripts read controller key from
this file as one fallback option).
Discovery on firmware 2.12: Request*ExtendedStatus opcodes (63/65/69)
NAK on this firmware — only the basic Request*Status opcodes are
implemented, so OmniClientV1 uses those (3 bytes/unit, 7 bytes/tstat,
4 bytes/aux records). HA still gets enough signal for polling; full
properties discovery uses streaming UploadNames instead.
Test totals: 387 passed, 1 skipped (existing fixture skip).