2 Commits

Author SHA1 Message Date
30b482a8cb HA integration: wire v1+UDP into the coordinator + config flow
OmniClientV1Adapter (src/omni_pca/v1/adapter.py)
  V2-shape facade over OmniClientV1. Exposes the OmniClient surface the
  HA coordinator was written against — get_system_information,
  list_*_names, get_object_properties (synthesized from streamed names),
  get_extended_status (chunked, routed to v1 typed status opcodes),
  get_object_status(AREA, ...) (derived from SystemStatus.area_alarms),
  events() (EventStream on v1 SystemEvents opcode 35), plus all the
  write-method shims.

  Chunks unit/zone/thermostat/aux polls per-type because firmware 2.12
  NAKs Request*Status with >~62 records in one shot (verified live).
  Falls back to "Area 1".."Area 8" when the UploadNames stream returns
  zero areas — common on panels where the installer didn't name them.

custom_components/omni_pca/coordinator.py
  _ensure_connected picks OmniClientV1Adapter for transport=udp. New
  _walk_properties_v1 replaces the v2 RequestProperties walk with a
  name-stream + synthesized-Properties pass.

custom_components/omni_pca/config_flow.py
  _probe routes to OmniClientV1Adapter for transport=udp instead of
  trying to drive v2 OmniClient over UDP (which silently dropped after
  handshake, per the earlier diagnosis).

src/omni_pca/events.py
  parse_events / _ensure_system_events / EventStream now take an
  expected_opcode arg (default v2 SystemEvents=55, v1 callers pass 35).
  Word format is byte-identical between v1 and v2, so the typed-event
  decoder is unchanged.

src/omni_pca/v1/client.py
  _range_status supports the long-form RequestUnitStatus (BE u16
  start/end) so panels with unit indices > 255 (sprinklers, flags) work.

Verified end-to-end against firmware 2.12 panel at 192.168.1.9:
  config entries:
    state=loaded  Omni Pro II (host.docker.internal)  (mock)
    state=loaded  Omni Pro II (192.168.1.9)           (real, v1+UDP)
  real-panel entities created in HA: 96 (30 binary_sensor, 26 light,
  15 switch, 13 button, 9 sensor, 3 climate)
  cross-check: light.omni_pro_ii_front_porch_2 = on  (matches live
  probe: unit #2 'FRONT PORCH' state=0x01 brightness=100)

dev/probe_v1_coordinator.py
  Coordinator-shaped end-to-end smoke test against the real panel
  without HA — drives the full discovery + poll cycle through the
  adapter. Useful for regression-checking the v1 wire path.

dev/add_real_panel.py
  Programmatically adds the real-panel config entry to the dev HA
  stack via the REST config-flow endpoints. Idempotent.
2026-05-11 01:30:49 -06:00
92c8b695b4 v1-over-UDP: parallel OmniClientV1 for panels that listen UDP-only
Some Omni network modules are configured for UDP, in which case PC Access
falls back to the v1 wire protocol (OmniLinkMessage outer = 0x10, inner
StartChar 0x5A, typed Request*Status opcodes) instead of v2's TCP path
(OmniLink2Message + StartChar 0x21 + parameterised RequestProperties).
This adds a parallel implementation rather than overloading the v2 path.

omni_pca/v1/
  connection.py   UDP-only OmniConnectionV1; reuses crypto + handshake,
                  routes post-handshake messages through OmniLinkMessage
                  (0x10) wrapping v1 inner format. Adds iter_streaming
                  for the lock-step UploadNames/Acknowledge/EOD pattern.
  messages.py     Block parsers for the typed v1 status replies (zone,
                  unit, thermostat, aux), v1 SystemStatus, and NameData
                  (handles both one-byte and two-byte NameNumber forms).
  client.py       OmniClientV1: read API (get_system_information,
                  get_*_status), discovery (iter_names + list_*_names),
                  write API (execute_command, execute_security_command,
                  turn_unit_*, set_unit_level, bypass/restore_zone,
                  execute_button, set_thermostat_*). acknowledge_alerts
                  is a no-op (v1 has no equivalent opcode).

Discovery uses bare UploadNames; panel streams every defined name across
all types in a fixed order with per-record Acknowledge. Verified against
firmware 2.12 — pulled 16 zones, 44 units, 16 buttons, 8 codes,
2 thermostats, 8 messages in one stream.

src/omni_pca/message.py
  Fix flipped START_CHAR_V1_* constants. enuOmniLinkMessageFormat says
  Addressable=0x41 and NonAddressable=0x5A; our names had them swapped.
  Wire bytes were unchanged, so existing tests kept passing — but
  encode_v1() with no serial_address now correctly emits 0x5A, which
  is what UDP needs.

tests/
  test_v1_messages.py        22 cases; payloads are real wire captures
                              from a firmware-2.12 panel via probe_v1_recon.
  test_v1_client_commands.py 20 cases; payload-packing for the Command
                              and ExecuteSecurityCommand opcodes,
                              including BE u16 parameter2 and the
                              digit-by-digit security code form.

dev/
  probe_v1.py        Phase-1 smoke: handshake + RequestSystemInformation.
  probe_v1_recon.py  Raw opcode dump for protocol reconnaissance.
  probe_v1_stream.py Streaming UploadNames flow exploration.
  probe_v1_client.py Full read-path smoke test via OmniClientV1.
  probe_v1_write.py  Live no-op execute_command round-trip.

.gitignore: ignore dev/.omni_key (probe scripts read controller key from
this file as one fallback option).

Discovery on firmware 2.12: Request*ExtendedStatus opcodes (63/65/69)
NAK on this firmware — only the basic Request*Status opcodes are
implemented, so OmniClientV1 uses those (3 bytes/unit, 7 bytes/tstat,
4 bytes/aux records). HA still gets enough signal for polling; full
properties discovery uses streaming UploadNames instead.

Test totals: 387 passed, 1 skipped (existing fixture skip).
2026-05-11 01:08:01 -06:00