7f82dbbbfa UDP transport: parallel codepath in OmniConnection + MockPanel
The C# decompile shows enuOmniLinkConnectionType has both Network_TCP=4
and Network_UDP=3 (clsOmniLinkConnection.cs uses udpSend/tcpSend
parallel paths), and clsHAC carries an enuPreferredNetworkProtocol
{TCP, UDP} per-installation byte. User reports their panel is
configured for UDP. The TCP-only assumption was too narrow.

Wire format is identical: same Packet/Message framing, same handshake,
same per-block whitening, same opcodes, same port. Only differences:
* UDP is connectionless; each datagram = one Packet (no stream framing)
* UDP needs explicit retry-on-timeout for reliability

src/omni_pca/connection.py:
- New constructor args: transport: Literal['tcp','udp']='tcp',
  udp_retry_count: int = 3
- connect()/close() branch on transport — TCP keeps the existing
  asyncio.open_connection + StreamReader/Writer + reader_task path;
  UDP uses asyncio.get_running_loop().create_datagram_endpoint with
  remote_addr= so transport.sendto(data) works without per-datagram
  addrs. The reader_task is TCP-only.
- _write_packet branches between writer.write and udp_transport.sendto
- request() loops up to (1 + udp_retry_count) attempts on UDP, retrying
  on RequestTimeoutError; TCP gets a single attempt (existing behavior)
- New _OmniDatagramProtocol that decodes each datagram into a Packet
  and delegates to the shared _dispatch (which already knows how to
  route handshake / solicited / unsolicited)

src/omni_pca/mock_panel.py:
- serve(transport='tcp'|'udp') public arg; defaults preserve existing
  TCP behavior. Internally splits into _serve_tcp / _serve_udp.
- New _MockServerDatagramProtocol that mirrors _handle_client for UDP.
  Tracks one active client by addr (single-session, matches Omni's
  single-client constraint). Reuses the panel's existing _dispatch_v2,
  _reply_*, _build_* helpers — the dispatch logic is unchanged, only
  the transport framing differs.
- New _schedule_udp_push for synthesized SystemEvents (seq=0) push
  to the active client's addr after state mutations.

src/omni_pca/client.py:
- OmniClient gains transport= and udp_retry_count= kwargs that pass
  through to OmniConnection. Default is 'tcp' so existing callers
  are unaffected.

tests/test_e2e_udp.py — 6 e2e tests:
- handshake roundtrip
- get_system_information
- arm area with right code
- arm with wrong code -> CommandFailedError
- turn unit on -> push UnitStateChanged event
- wrong ControllerKey -> HandshakeError

All run under 0.2s. Combined with the existing TCP suite: 357 tests
pass (was 351), ruff clean across src/ tests/.

The HA integration's config_flow still defaults to TCP; users on UDP
panels can manually set transport= via the OmniClient init path. A
follow-up commit will add transport to the HA config flow as a
dropdown option.
2026-05-10 20:42:43 -06:00
c26db62959 Library v1.0 phase C: stateful mock + e2e for the new surface
src/omni_pca/client.py — wire OmniClient.events() that returns an async
iterator over typed SystemEvent objects (built on events.EventStream).

src/omni_pca/mock_panel.py — substantial expansion:
- Per-object state dataclasses (MockUnitState, MockAreaState, MockZoneState,
  MockThermostatState) plus user_codes table for security validation
- Backward-compat: existing callers passing {idx: 'NAME'} strings still work
  via __post_init__ string-promotion to the matching Mock*State instance
- New opcode handlers:
    Command (20)                  -> Ack with state mutation, dispatches
                                     UNIT_ON/OFF/LEVEL, BYPASS/RESTORE_ZONE,
                                     SET_THERMOSTAT_HEAT/COOL/SYS/FAN/HOLD
    ExecuteSecurityCommand (74)   -> Ack on valid code (mode applied);
                                     Nak on invalid code
    RequestStatus (34)            -> Status (35) for Zone/Unit/Area/Thermostat
                                     hard-coded record sizes per
                                     clsOL2MsgStatus.cs:13-27
    RequestExtendedStatus (58)    -> ExtendedStatus (59) with object_length
                                     prefix, richer fields per object type
    AcknowledgeAlerts (60)        -> Ack
- Synthesized SystemEvents (55) push on state change with seq=0; events round-
  trip cleanly through events.parse_events() (validated by tests, not just
  asserted in code)

tests/test_e2e_client_mock.py — +9 e2e tests covering arm/disarm with code
validation, unit on/off/level, zone bypass/restore, thermostat setpoint,
push events for arming and unit changes, acknowledge_alerts.

203 passed (was 194), 2 skipped (HA harness + .pca fixture). Ruff clean.

Library v1.0 surface complete: read-only, command, status, extended status,
events. Next: rebuild the HA custom_component on top of this.
2026-05-10 14:28:35 -06:00
68cf44a585 Library v1.0 phase B: command opcodes + typed system events
src/omni_pca/commands.py — Command IntEnum (64 values, sourced from
enuUnitCommand.cs which is the canonical 'enuCommand' despite the misleading
name) + SecurityCommandResponse + CommandFailedError exception. Notable
discovery: enuUnitCommand.UserSetting (104) is actually EXECUTE_PROGRAM;
renamed for clarity, C# alias documented inline.

src/omni_pca/client.py — 18 new methods on OmniClient:
  Core: execute_command, execute_security_command, acknowledge_alerts,
        get_object_status, get_extended_status
  Wrappers: turn_unit_on/off, set_unit_level, bypass_zone, restore_zone,
        set_thermostat_{system,fan,hold}_mode,
        set_thermostat_{heat,cool}_setpoint_raw,
        execute_button, execute_program, show_message, clear_message
  All command methods raise CommandFailedError on Nak.

src/omni_pca/events.py — typed SystemEvents (opcode 55) decoder.
- EventType IntEnum (28 dispatch tags)
- 26 SystemEvent subclasses + UnknownEvent catch-all
  Includes: ZoneStateChanged, UnitStateChanged, ArmingChanged,
  AlarmActivated/Cleared, AcLost/Restored, BatteryLow/Restored,
  PhoneLine{Off,On,Dead,Restored}, UserMacroButton, ProLinkMessage,
  CentraLiteSwitch, X10CodeReceived, AllOnOff, DcmTrouble/Ok,
  EnergyCostChanged, CameraTrigger, AccessReaderEvent, UpbLinkEvent
- SystemEvents packets carry MULTIPLE events; public API is
  parse_events(message) -> list[SystemEvent], plus SystemEvent.parse()
- EventStream helper that flattens batches across messages
- Wiring of OmniClient.events() left for next pass

55 new tests across both files. 194 pass, 2 pre-existing skips. Ruff clean.
2026-05-10 14:17:12 -06:00
1901d6ec87 Async client + mock panel + e2e roundtrip
src/omni_pca/connection.py — low-level OmniConnection
- 4-step secure-session handshake (NewSession, SecureSession)
- Per-direction monotonic seq with 0xFFFF -> 1 wraparound (skips 0)
- TCP framing: read first 16-byte block, decrypt, learn length, read rest
- Reader task dispatches solicited replies to Future, unsolicited to queue
- Custom exceptions: HandshakeError, InvalidEncryptionKeyError, ProtocolError,
  RequestTimeoutError

src/omni_pca/models.py — typed response objects
- SystemInformation (with model_name lookup), SystemStatus, ZoneProperties,
  UnitProperties, AreaProperties — all frozen+slots dataclasses with
  .parse(payload) classmethods

src/omni_pca/client.py — high-level OmniClient
- get_system_information / get_system_status / get_object_properties
- list_{zone,unit,area}_names walks via RequestProperties rel=1
- subscribe(callback) for unsolicited messages

src/omni_pca/mock_panel.py — async TCP server emulating an Omni Pro II
- Full handshake (controller side), seedable MockState
- Implements RequestSystemInformation, RequestSystemStatus,
  RequestProperties (Zone/Unit/Area, both absolute and rel=1 iteration
  with EOD termination); Nak for everything else
- 'omni-pca mock-panel' CLI subcommand

tests/ — 85 passed, 1 skip (live fixture)
- 23 unit tests for connection/models/client (canned-server fixtures)
- 7 unit tests for mock panel (raw protocol drive)
- 6 e2e tests: real OmniClient over real TCP to real MockPanel,
  proves handshake + AES + whitening + sequencing all agree
2026-05-10 13:02:49 -06:00