pca_file: ZoneOptions + thermostat type/areas — per-object props done
Closes out the per-object property triad. These three fields live deep in the installer section past the zone-area / button-area-group arrays (clsHAC.cs:3290-3416): 3330..3393: Thermostats[1..64].Areas (area-membership bitmask) 3397..3460: Thermostats[1..64].Type (raw enuThermostatType) 3553..3728: Zones[1..176].ZoneOptions (raw options byte) Offsets derived from the OMNI_PRO_II CAP constants (numConsoles=16, numTstats=64, numDCMCodes=16, numMessageGroups=16, numSerialPorts=6, numSCI+numUART=5) plus its feature set — SuperviseBell + SuperviseExteriorSounder + ZoneResistors + Addressable + UPB all present, contributing exactly 9 conditional bytes before ReportBypassRestore. Verified empirically: ZoneOptions is a clean 176-byte run of the default value 4, bounded by CrossZoneTimer=60 as the canary byte just before it. New PcaAccount fields: zone_options, thermostat_types, thermostat_areas. MockZoneState gains `options`, MockThermostatState gains `thermostat_type` + `areas`. The mock's zone and thermostat Properties replies now serve the real values instead of the hardcoded 0 / 1 they used before — so HA discovery against MockState.from_pca gets the complete per-object property set. Live fixture: all 176 zones at the default options=4, both named thermostats type 1, thermostat areas 0xFF (all) → normalised to area 1 in the mock (consistent with the unit-area handling). With this the OMNI_PRO_II SetupData decode is functionally complete for every per-object property a consumer would want — zones, units, areas, thermostats all carry type + area + options sourced from the file rather than faked. Full suite: 499 passed, 1 skipped.
This commit is contained in:
parent
e61e37a3fc
commit
c7eb92122b
@ -173,6 +173,7 @@ class MockZoneState:
|
||||
loop: int = 0 # analog loop reading
|
||||
zone_type: int = 0 # raw enuZoneType byte (0=EntryExit default)
|
||||
area: int = 1 # 1-based area assignment
|
||||
options: int = 0 # raw ZoneOptions bitmask (SetupData; panel default 4)
|
||||
|
||||
@property
|
||||
def status_byte(self) -> int:
|
||||
@ -217,6 +218,8 @@ class MockThermostatState:
|
||||
outdoor_temperature_raw: int = 0
|
||||
horc_status: int = 0
|
||||
status: int = 1 # 1 = communicating with the panel
|
||||
thermostat_type: int = 1 # raw enuThermostatType (1=AutoHeatCool)
|
||||
areas: int = 0x01 # 8-bit area-membership bitmask
|
||||
|
||||
|
||||
@dataclass
|
||||
@ -348,6 +351,7 @@ class MockState:
|
||||
name=n,
|
||||
zone_type=acct.zone_types.get(i, 0),
|
||||
area=acct.zone_areas.get(i, 1),
|
||||
options=acct.zone_options.get(i, 0),
|
||||
)
|
||||
for i, n in acct.zone_names.items()
|
||||
},
|
||||
@ -382,7 +386,17 @@ class MockState:
|
||||
for i in sorted(in_use_areas)
|
||||
},
|
||||
"thermostats": {
|
||||
i: MockThermostatState(name=n)
|
||||
i: MockThermostatState(
|
||||
name=n,
|
||||
thermostat_type=acct.thermostat_types.get(i, 1),
|
||||
# 0xFF (uninitialised → "all areas") normalises to
|
||||
# area 1 only, consistent with the unit-area handling.
|
||||
areas=(
|
||||
0x01
|
||||
if acct.thermostat_areas.get(i, 0xFF) == 0xFF
|
||||
else acct.thermostat_areas[i]
|
||||
),
|
||||
)
|
||||
for i, n in acct.thermostat_names.items()
|
||||
},
|
||||
"buttons": {
|
||||
@ -987,7 +1001,7 @@ class MockPanel:
|
||||
zone.loop if zone else 0,
|
||||
zone.zone_type if zone else 0,
|
||||
zone.area if zone else 1,
|
||||
0, # Options (not yet sourced from SetupData)
|
||||
zone.options if zone else 0,
|
||||
]
|
||||
)
|
||||
+ self.state.zone_name_bytes(index)
|
||||
@ -1045,7 +1059,7 @@ class MockPanel:
|
||||
t.system_mode if t else 0,
|
||||
t.fan_mode if t else 0,
|
||||
t.hold_mode if t else 0,
|
||||
1, # thermostat type: AUTO_HEAT_COOL
|
||||
t.thermostat_type if t else 1,
|
||||
]
|
||||
)
|
||||
+ self.state.thermostat_name_bytes(index)
|
||||
|
||||
@ -263,6 +263,23 @@ class PcaAccount:
|
||||
# zone to area 1. Empty dict when SetupData wasn't walked successfully.
|
||||
zone_areas: dict[int, int] = field(default_factory=dict)
|
||||
|
||||
# Per-zone options bitmask from SetupData (clsHAC.cs:3405-3415).
|
||||
# Raw byte, range-checked by the firmware to 0..7 (0..15 on EURO
|
||||
# EN50131 panels) with a default of 4. The bits select per-zone
|
||||
# behaviours (cross-zoning, swinger-shutdown participation, etc.);
|
||||
# the precise bit semantics aren't decoded here. Keys are 1-based
|
||||
# zone slots (1..numZones).
|
||||
zone_options: dict[int, int] = field(default_factory=dict)
|
||||
|
||||
# Per-thermostat type + area assignment from SetupData
|
||||
# (clsHAC.cs:3298-3320). ``thermostat_types`` values are raw
|
||||
# ``enuThermostatType`` bytes (0=NotUsed/None, 1=AutoHeatCool, …);
|
||||
# ``thermostat_areas`` values are 8-bit area-membership bitmasks
|
||||
# (0xFF = all areas, the panel default). Keys are 1-based
|
||||
# thermostat slots (1..numTstats).
|
||||
thermostat_types: dict[int, int] = field(default_factory=dict)
|
||||
thermostat_areas: dict[int, int] = field(default_factory=dict)
|
||||
|
||||
# Per-area entry/exit delay (seconds) from SetupData user section.
|
||||
# Keys are 1-based area numbers (1..numAreas); typical values are
|
||||
# 30/60 (entry) and 60/90 (exit). Unused areas carry the panel
|
||||
@ -617,6 +634,26 @@ _CAP_OMNI_PRO_II: dict[str, int] = {
|
||||
"flagOutAreaGroupsOffset": 3059, # (lastFlagOut-firstFlagOut+8)/8 = 15 bytes, 1 group/8 flags
|
||||
"expEncAreaGroupsOffset": 3074, # (lastExpEncOut-firstExpEncOut+4)/4 = 32 bytes, 1 group/4 outputs
|
||||
"zoneAreaOffset": 3106,
|
||||
# Past the zone-area / button-area-group arrays, the installer
|
||||
# section continues (clsHAC.cs:3290-3416). Offsets derived from the
|
||||
# OMNI_PRO_II CAP constants — numConsoles=16, numTstats=64,
|
||||
# numDCMCodes=16, numMessageGroups=16, numSerialPorts=6 (→4 rates),
|
||||
# numSCI+numUART=5 (→3 protocols) — and the feature set
|
||||
# (SuperviseBell + SuperviseExteriorSounder + ZoneResistors +
|
||||
# Addressable + UPB all present, contributing 9 conditional bytes
|
||||
# before ReportBypassRestore). Verified empirically:
|
||||
# 3298..3313: Consoles[1..16].Area
|
||||
# 3314..3329: Consoles[1..16].Global
|
||||
# 3330..3393: Thermostats[1..64].Areas (area-membership bitmask)
|
||||
# 3394: TimeAdj / 3395: AlarmResetTime / 3396: ArmingConfirmation
|
||||
# 3397..3460: Thermostats[1..64].Type (enuThermostatType)
|
||||
# ... DCM open/close codes, message groups, serial config,
|
||||
# feature-conditional fields, area exit/unvacated flags ...
|
||||
# 3552: CrossZoneTimer (boundary canary = 60)
|
||||
# 3553..3728: Zones[1..176].ZoneOptions (raw options byte, default 4)
|
||||
"thermostatAreasOffset": 3330,
|
||||
"thermostatTypeOffset": 3397,
|
||||
"zoneOptionsOffset": 3553,
|
||||
# Unit index ranges → unit type derivation. Per CAP for OMNI_PRO_II:
|
||||
"firstX10": 1, "lastX10": 256,
|
||||
"firstExpEncOut": 257, "lastExpEncOut": 384,
|
||||
@ -836,6 +873,9 @@ class _ConnectionWalk:
|
||||
message_names: dict[int, str] = field(default_factory=dict)
|
||||
zone_types: dict[int, int] = field(default_factory=dict)
|
||||
zone_areas: dict[int, int] = field(default_factory=dict)
|
||||
zone_options: dict[int, int] = field(default_factory=dict)
|
||||
thermostat_types: dict[int, int] = field(default_factory=dict)
|
||||
thermostat_areas: dict[int, int] = field(default_factory=dict)
|
||||
area_entry_delays: dict[int, int] = field(default_factory=dict)
|
||||
area_exit_delays: dict[int, int] = field(default_factory=dict)
|
||||
area_entry_chime: dict[int, bool] = field(default_factory=dict)
|
||||
@ -945,6 +985,25 @@ def _walk_to_connection(r: PcaReader, cap: dict[str, int]) -> _ConnectionWalk:
|
||||
for slot in range(1, cap["max_zones"] + 1):
|
||||
zone_areas[slot] = setup_data[za_off + slot - 1]
|
||||
|
||||
zo_off = cap.get("zoneOptionsOffset")
|
||||
zone_options: dict[int, int] = {}
|
||||
if zo_off is not None and zo_off + cap["max_zones"] <= len(setup_data):
|
||||
for slot in range(1, cap["max_zones"] + 1):
|
||||
zone_options[slot] = setup_data[zo_off + slot - 1]
|
||||
|
||||
# Per-thermostat type + area assignment (64 slots on OMNI_PRO_II).
|
||||
n_tstats = cap.get("max_tstats", 0)
|
||||
tt_off = cap.get("thermostatTypeOffset")
|
||||
thermostat_types: dict[int, int] = {}
|
||||
if tt_off is not None and tt_off + n_tstats <= len(setup_data):
|
||||
for slot in range(1, n_tstats + 1):
|
||||
thermostat_types[slot] = setup_data[tt_off + slot - 1]
|
||||
tha_off = cap.get("thermostatAreasOffset")
|
||||
thermostat_areas: dict[int, int] = {}
|
||||
if tha_off is not None and tha_off + n_tstats <= len(setup_data):
|
||||
for slot in range(1, n_tstats + 1):
|
||||
thermostat_areas[slot] = setup_data[tha_off + slot - 1]
|
||||
|
||||
# Per-area entry/exit delays from the user section.
|
||||
num_areas = cap.get("max_areas", 0)
|
||||
def _read_area_byte_array(offset_key: str) -> dict[int, int]:
|
||||
@ -1252,6 +1311,9 @@ def _walk_to_connection(r: PcaReader, cap: dict[str, int]) -> _ConnectionWalk:
|
||||
message_names=message_names,
|
||||
zone_types=zone_types,
|
||||
zone_areas=zone_areas,
|
||||
zone_options=zone_options,
|
||||
thermostat_types=thermostat_types,
|
||||
thermostat_areas=thermostat_areas,
|
||||
area_entry_delays=area_entry_delays,
|
||||
area_exit_delays=area_exit_delays,
|
||||
area_entry_chime=area_entry_chime,
|
||||
@ -1394,6 +1456,9 @@ def parse_pca_file(path_or_bytes: str | os.PathLike[str] | bytes, key: int) -> P
|
||||
account.message_names = walk.message_names
|
||||
account.zone_types = walk.zone_types
|
||||
account.zone_areas = walk.zone_areas
|
||||
account.zone_options = walk.zone_options
|
||||
account.thermostat_types = walk.thermostat_types
|
||||
account.thermostat_areas = walk.thermostat_areas
|
||||
account.area_entry_delays = walk.area_entry_delays
|
||||
account.area_exit_delays = walk.area_exit_delays
|
||||
account.area_entry_chime = walk.area_entry_chime
|
||||
|
||||
@ -475,6 +475,20 @@ async def test_mockstate_from_pca_serves_real_panel_programs() -> None:
|
||||
# zones in area 1.
|
||||
for slot, zone in state.zones.items():
|
||||
assert zone.area == 1, f"slot {slot} expected area=1 got {zone.area}"
|
||||
# ZoneOptions — every zone carries the panel-default 4 in this fixture.
|
||||
for slot, zone in state.zones.items():
|
||||
assert zone.options == 4, f"slot {slot} expected options=4 got {zone.options}"
|
||||
assert all(v == 4 for v in acct.zone_options.values())
|
||||
assert len(acct.zone_options) == 176
|
||||
|
||||
# Thermostat type + area from SetupData. The two named thermostats
|
||||
# (DOWNSTAIRS, UPSTAIRS) are type 1; areas were 0xFF (all) →
|
||||
# normalised to area 1 only in MockState.
|
||||
assert acct.thermostat_types[1] == 1
|
||||
assert acct.thermostat_types[2] == 1
|
||||
assert len(acct.thermostat_types) == 64
|
||||
assert state.thermostats[1].thermostat_type == 1
|
||||
assert state.thermostats[1].areas == 0x01
|
||||
|
||||
panel = MockPanel(controller_key=CONTROLLER_KEY, state=state)
|
||||
async with panel.serve(transport="tcp") as (host, port):
|
||||
|
||||
Loading…