Compare commits
1 Commits
master
...
feature/tu
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
5739cc30ee |
@ -1,8 +1,27 @@
|
||||
# WireViz Tutorial
|
||||
## Bare-bones example
|
||||
|
||||
* Minimum working example
|
||||
* Only 1-to-1 sequential wiring
|
||||
This is a minimal example that shows the basic WireViz syntax. A WireViz file consists of three sections: `connectors:` and `cables:` specify the components to be used, while `connections:` creates the links between components.
|
||||
|
||||
### `connectors:`
|
||||
|
||||
Each connector has a designator (a unique name) and can contain various parameters. The minimum requirement is `pincount`, specifying the number of ports to which wires can be attached.
|
||||
|
||||
### `cables:`
|
||||
|
||||
A cable is a collection of wires (for bundles of individual wires, see below). Just like connectors, they have a unique designator and a `wirecount`, i.e. the number of wires inside the cable.
|
||||
|
||||
In this example, the cable is also given a `length`. This length must be specified in meters.
|
||||
|
||||
### `connections:`
|
||||
|
||||
This section is a list of connection sets. In this example, only one set is necessary.
|
||||
|
||||
The set consists of three parts: A starting connector (`X1`), a cable (`W1`) and a destination connector (`X2`).
|
||||
|
||||
This set specifies that connectos 1 through 4 of `X1` should go straight through wires 1 through 4 of `W1` and into connectors 1 through 4 of `X2`: A straight 1-to-1 wiring.
|
||||
|
||||
For other ways of defining connection sets, see below.
|
||||
|
||||
[Source](tutorial01.yml):
|
||||
|
||||
|
||||
@ -1,4 +1,23 @@
|
||||
## Bare-bones example
|
||||
|
||||
* Minimum working example
|
||||
* Only 1-to-1 sequential wiring
|
||||
his is a minimal example that shows the basic WireViz syntax. A WireViz file consists of three sections: `connectors:` and `cables:` specify the components to be used, while `connections:` creates the links between components.
|
||||
|
||||
### `connectors`
|
||||
|
||||
Each connector has a designator (a unique name) and can contain various parameters. The minimum requirement is `pincount`, specifying the number of ports to which wires can be attached.
|
||||
|
||||
### `cables`
|
||||
|
||||
A cable is a collection of wires (for bundles of individual wires, see below). Just like connectors, they have a unique designator and a `wirecount`, i.e. the number of wires inside the cable.
|
||||
|
||||
In this example, the cable is also given a `length`. This length must be specified in meters.
|
||||
|
||||
### `connections`
|
||||
|
||||
This section is a list of connection sets. In this example, only one set is necessary.
|
||||
|
||||
The set consists of three parts: A starting connector (`X1`), a cable (`W1`) and a destination connector (`X2`).
|
||||
|
||||
This set specifies that connectos 1 through 4 of `X1` should go straight through wires 1 through 4 of `W1` and into connectors 1 through 4 of `X2`: A straight 1-to-1 wiring.
|
||||
|
||||
For other ways of defining connection sets, see below.
|
||||
|
||||
Loading…
x
Reference in New Issue
Block a user